liquid distributor design calculation

𝐿 𝑎 𝜇 𝑉 𝑎 Corresponding Reynolds Number N Re for the system can be obtained from GPSA Data book1 Fig. Calculate the Reynolds number Rei of the inlet stream to the pipe distributor using the following equation.


Column Internals Explained Part 2 Separation Technologies

Liquid Distribution Liquid distributors are used above each bed of packing in a packed column to provide uniform liquid distribution.

. 01-25 gpmft 025-60 m3hm2 n Tower diameter. Ideally a distributor with large orifices a moderate drip point density and a moderate head level would provide an efficient fouling-resistant design. PROCESS DESIGN OF GAS VAPOR-LIQUID SEPARATORS PROJECT STANDARDS AND SPECIFICATIONS Page 5 of 45 Rev.

These styles of liquid distributors consist of a perforated deck with holes or drip tubes for the liquid and round or rectangular risers for the vapor. The scope of the guide is summarized in its clause headings. Siretb Chemical 17 May 10 0236.

Since N Re for this case lies between 2 and 500 Terminal settling velocity V t. In a randomly packed tower the liquid tends to. DESIGN CALCULATIONS 71 Selection of Packing Size 72 Rough Design 73 Detailed Design and Rating 8 LIQUID DISTRIBUTION AND REDISTRIBUTION 81 Basic Concepts 82 Pour Point Density 83 Peripheral Irrigation - the Wall Zone 84 Distributor Levelness 85 Maximum Bed Height and Liquid Redistribution.

Beams or on packing with special support grid n Redistribution. 4 Design Philosophy 5 Performance Guarantees 6 Description of Packed Column Internals 7 Design Calculations 8 Liquid Distribution and Redistribution 9 Practical Aspects of Packed Column Design In addition Appendices give examples of design calculations by various methods for both. If higher turndown ratios are required taller risers can be used.

Wash Tank Distributor 14 Testing and New Developments 15 In industrial process equipments liquid-liquid mixtures are produced by essentially two different mechanisms. And h PD is the distributor head loss on the vapor side in. The distributordepending on its design featuresis generally located 6 to 8 in.

Liquid distribution in the packing is calculated in a top down sequence following a three-step distribution mechanism which considers the geometrical shape of the packing as well as the operating parameters liquid and gas load. Detailed information about the TUMWelChem Cell Model is presented in Hanusch et al. H OA h O h PD 1 where h OA is the total liquid head in the liquid distributor in.

Adequate liquid head in the distributor plays a significant role in dissipating momentum and minimising the effects of flow anomalies throughout the distributor. Trough wall orifices with guide tubes n 2Liquid rates. Graphical Determination of a Distillation Column Design Step 1.

H O is the orifice head in. Unlike a plate column where the gas-liquid contact is stagewise a packed columns gas-liquid contact is continuous. 3 ft 900 mm n Support features.

The function of the distributor is therefore to convert a point source into a distributed flow. In the same column operating at the same load but under a head of ho 3 mm the number required would be Z 80. 900 mm ID with minimum liquid rates in excess of 2 gpmft25 m3hm2.

The distributor type determines vertical spacing and the proper distance needed. H Height tangent to tangent of vessel m. Let us straight away get to the steps for sizing a Perforated Pipe Liquid distributor.

Separate liquid collector n Standard features 21 turndown ratio. My experience is that such tests are essential. Liquid distributor test for columns.

Determine Process Operation Variables Assumed feed rate composition purity of distillate and bottoms and the quality of the feed are known. Perform overall material and component balances to determine the compositions of the distillate and bottoms. What should be verified is the evenness homogeneity of the liquid distribution m3hr of liquid per m2 of section at different areas and at least at nominal and minimum flow rate.

This type of liquid distributor has long been the primary device selected for standard performance random packing where liquid flow rates are moderate to high levels. Find the required pressure drop ΔP o across the distributor holes by multiplying the greater of E k or ΔP p by 10. While the liquid flows down the vapor or gas will go up the column in a counter-current manner.

Rei 127Qρ. In a gravity head distributor this is the sum of the two components. Thus if the liquid load is uL 1 m3m2h and the head is ho 1 mm the number of liquid outlets Z required per square metre of column cross-section would be Z 150 in a plate distributor with perforations of d 3 mm diameter.

In this design the liquid will flow down the column and pass through the packaging material. Liquid distribution in the packing is estimated in dependence of the liquid distributor design. An orifice typepan liquid distributor the most conventional type allows gas to pass the plate through risers while liquid flows through openings in the floor.

An overall maldistribution quality is determined as a characteristic value for evaluation. L G x ρg ρl05 0042002778 x 11846110005 000497 Use the 000497 as ordinate and pressure drop of 1471 NSqmm find the abscissa from the below graph. If the calculated value of ΔP o is less than 175 kPa 025 psi make it equal to at least 175 kPa 025 psi.

Diameters greater than 36 in. In a liquid distributor it is assumed that the liquid enters via a pipe nozzle of some sort and the function of the distributor is to spread the liquid evenly over the cross section of the tower. Liquid leaving the packing L inlet liquid flow rate Component removed 00207 00214 00420 KgSec.

According to Bernoullis equation total head at a ny given point in liquid unde r motion is the sum of pressure velocity and elevation heads. 900 mm Orifices in base Liquid rates between 2 and 16 gpmft25 40 m3hm2 The Model 126 Intalox distributor and Model 127 redistributor are designed for towers greater than 36 in. Initially set the pipe size of the pipe distributor same as the pipe size feeding the pipe distributor Step 2.

The standard design has a turndown ratio of 21 and the pressure drop in water is typically 02 06. A Mixing of the phases in either purpose- built equipment mechanical mixers static mixers where pressure energy is applied to increase the surface free en-. 7 Model 186 Trough Distributor Model 196 Packed Trough Very Low Flow Distributor n Metering device.

150 to 200 mm above the packing. L Length of perforated distributor pipe m ft J dimensionless factor Use J 035 as an initial value Step 6. Z g V h P 2 2 2 Where h total head feet P pressure head feet V velocity ftsec g gravitational acceleration 322 fts2.

Liquid distributor test for columns. Design of the Liquid outlet nozzle and the Vortex Breaker. 01 April 2011 g Local acceleration due to gravity ms².


Importance Of Liquid Distributors Part 1 Mach Engineering


Column Internals Explained Part 2 Separation Technologies


Location Of Liquid Distributor Relative To The Packing The Following Download Scientific Diagram


2


Distributors Pressure Drop Brewiki


2


Perforated Pipe Distributor Sizing Calculations Cheresources Com Community


Column Internals Explained Part 2 Separation Technologies

0 comments

Post a Comment